Home >  OEM/ODM > OEM/ODM Services > ups> Online Transformerless UPS> YDC3300 (10-40kVA)
YDC3300
10-40kVA
 
YDC3300 series UPS is a three-phase in and three-phase out high frequency UPS with medium and large power capacity. Equipped with three-level inverter topology, it results in high efficiency reaching 95.5%. With higher power density, smaller footprint, it takes the leading position in the UPS industry with same power capacity; Adopting unique power unit redundancy design technology, decrease the abnormity risk of system after single-point failure, greatly increase the system reliability. For user, it is your best choice with high investment rate.
General Features

● Online double conversion

● Output transfer time is 0ms

● PFC technology

● Full digital control(DSP)

● Output power factor: 0.9

● Input current harmonic: 3%

● Support economic (ECO) operation mode

● Optimization battery group, the quantity of battery: 10-30k(16/18/20 pcs optional), 40-80k(32/34/36/38/40 pcs optional)

● Wide input voltage range: 208~478Vac

● Wide input frequency range: 40~70Hz

● Cold start

● Communication port: USB, RS232, RS485, Parallel port, Dry contact

● Options: SNMP card/Relay card

● LCD/LED double display

● Intelligent charging management

● EPO function

● Common battery group

● The output can meet 100% unbalanced load

Technical Specification
MODEL YDC3310S/H YDC3315S/H YDC3320S/H YDC3330S/H YDC3340 YDC3360 YDC3380
Capacity (VA/Watts) 10k / 9k 15k / 13.5k 20k / 18k 30k / 27k 40k / 36k 60k / 54k 80k / 72k
INPUT
Nominal voltage 380/400/415Vac(3Ph+N+PE)
Operating
voltage range
208~478Vac
Operating
frequency range
45~55Hz at 50Hz / 54~66Hz at 60Hz(auto sensing) 40~70Hz
Power factor ≥0.99
Bypass voltage
 range
380Vac Max.voltage: +25%(optional +10%,+15%,+20% )
400Vac Max.voltage: +20% (optional +10%,+15%)
415Vac Max.voltage: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)
Bypass frequency
range 
Frequency synchronize tracing range:±10%
ECO range Same as the bypass
Harmonic
distortion (THDi)
≤3%(100% non-linear load)
OUTPUT
Rated voltage 380/400/415Vac(3Ph+N+PE)
Power factor 0.9
Voltage
 regulation
±1%
Frequency Line mode ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Bat. mode 50/60(±0.1)Hz
Crest factor 3:1
Harmonic
distortion
 (THDv)
≤2% with linear load
≤5% with non-linear load  
Efficiency 93.50% 94.50%
BATTERY
Battery voltage Standard unit:
 ±120Vdc
(20pcs 12V9Ah);
Long run unit optional voltage: ±96/±108/
±120Vdc(16/18/20
pcs optional)
Standard unit:
 ±120Vdc(2×20pcs 12V9Ah);
Long run unit optional voltage: ±96/±108/±120Vdc(16/18/20
 pcs optional)
Standard unit:
±120Vdc(3×20pcs 12V9Ah);Long run unit
 optional voltage: ±96/±108/±120Vdc(16/18/20pcs optional)
Optional voltage:
±192/±204/±216/±228/±240Vdc
(32/34/36/38/40 pcs optional)
Charging current
(A)(Charging
 current can be
 set according to
 battery capacity
   installed)
Standard unit: 1.35A
Long run unit:
Max.current 10A
Standard unit: 2.7A
Long run unit:
 Max.current 10A
Standard unit: 4.05A
Long run unit:
Max.current 15A
Max.current
15A
Max.current
30A
Max.current
 30A
SYSTEM FEATURES
Transfer time Utility to battery:0ms; Utility to bypass:0ms
Overload Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode
Short circuit Hold whole system
Communication
 interface
USB, RS232, RS485, Parallel port, REPO port, Dry contact, Intelligent slot, SNMP card(optional),
Relay card (optional), LBS port(only 60-80k)
ENVIRONMENT
Operating
 temperature
0~40℃
Storage
temperature
-25~55℃(No battery)
Humidity range 0~95% (Non-condensing)
Altitude <1500m. When >1500m, derating power for use
Noise level <55dB <58dB <63dB
PHYSICAL
Dimension
D×W×H (mm)
828×250×868 828×360×868
Net weight (kg) 115/57 170/63 171/64 223/71 73 118 122
STANDARDS
Safety  IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8