Home >  Products > Data Center Infrastructure > UPS> Lithium-ion UPS> Memopower Li 1-3kVA UPS with Lithium Batteries
Memopower Li Series with Lithium Batteries
1~3kVA PF:0.9

The Memopower Li series online UPS with LiFePO4 Lithium Batteries features long service time and high density. With smart battery management system it can improve the overall performance of the UPS and lengthen the warranty. This Long-life-span lithium-ion UPS can also shift your refresh cycle to be in line with your IT equipment, saving time and money spent on labor and replacement batteries.

General Features


●Ture Online DoubleConversion

●Lithium-ion Batteries built-in

●Smart BMS provides up-to-date insight

●Reduce Weight,improved performance and Lengthened Warranty

●Wide input voltage range for harsh environment

●Support generator

●Output power factor 0.9

●Up to 92% efficiency models available

●UL certificated

Technical Specification   

MODEL MP RT 1k S MP RT 1.5k S MP RT 2k S MP RT 3k S
Capacity 1000VA/900W 1000VA/1000W 1500VA/1350W 2000VA/1800W 3000VA/2700W
INPUT
Nominal voltage 100/110/115/120/125 Vac
Input voltage range 55~150 Vac (80~150Vac @ 100% load)
Power factor 0.99 (Full load)
Input connection NEMA 5-15P NEMA 5-20P NEMA L5-30P
Cord length 1.8m
FREQUENCY
Frequency range 40~70Hz (50/60Hz Auto-Sensing)
OUTPUT
Output voltage 100/110/115/120/125 Vac
Voltage regulation ±1%
Power factor 0.9 1.0 0.9
Output frequency Line mode 50/60Hz ± 4Hz
Bat. mode 50/60Hz ± 0.02Hz
Crest factor 3:01
Harmonic distortion (THDv) 3% Full linear load 2% Full linear load
  4% Full non-linear load
Transfer time AC mode to Bat.mode 0ms
Inverter to Bypass 4ms (Typical)
Output waveform Pure Sinewave
Output receptacles Programmable (Optional) 5-15R×4 5-20R×4 5-20R×3
Non-programmable 5-15R×4 L5-20R×1 (Optional) + 5-20R×4 L5-30R×15-20R×3
EFFICIENCY
AC mode 91% 91% 92% 92%
ECO mode 95% 95% 96% 96.50%
BATTERY
Battery number 2 3 3 4 4 6 6
Battery capacity 9Ah/12V
Typical recharging time 4hours (To 90% of full capacity)
Charging voltage 27.14 Vdc±1% 41.1 Vdc±1% 54.8 V dc±1% 82.2 Vdc±1%
Charging current (Max.) 2A
INDICATORS
LED / LCD display Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
ALARM
Battery mode Beeping every 4 seconds
Battery low Beeping every second
Overload Beeping twice every second
Fault Continously beeping
PHYSICAL
Dimension W×D×H 440×325×86.5mm 440×460 86.5mm 440×500×86.5mm 4 40×640×86.5mm
Net weight 14kg 16.5kg 17kg 19.5kg 21kg 26.7kg 27kg
ENVIRONMENT
Operating temperature 0~40 ºC
Storage temperature 25℃~55 (Without batteries)
Humidity range 0~95% (Non - condensing)
Altitude 0~3000 (1000~3000 derating required)
Noise level 45dB 55dB
STANDARDS
Safety UL1778 5th Edition CSA C22.2 NO.107.3-14
FCC FCC Part 15, Subpart B, ClassB ANSI C63.4-2014 FCC Part 15, Subpart B, ClassA ANSI C63.4-2014
Energy saving Energy Star 2.0
Transportation ISTA Procedure 2A