Line-interactive UPS-DG Family
600-3000VA
DG series line-interactive UPS is specially designed for Personal Computer with multi-functions. The lightweight, compact design perfectly fits the limited space. The UPS is equipped with two boosts and one buck AVR to stabilize the wide input voltage range. lt is also built-in with DC start function. This function enables the UPS to be started up without an AC power supply.
General Features
● Line Interactive UPS with simulated sinewave output
● Excellent microprocessor control guarantees high reliability(Internal self-diagnostic technology)
● Boost and buck AVR for voltage stabilization
● (wide input range with two boost and one buck control)
● Auto restart while AC is recovering
● Cold start function
Technical Specification
Model | DG600 | DG850 | DG1K | DG1.2K | DG1.5K | DG2K | DG2.4K | DG3K |
Capacity(VA/Watts) | 600 / 360 | 800 / 480 | 1000 / 600 | 1200 / 720 | 1500 / 900 | 2000 / 1200 | 2400 / 1440 | 3000 / 1800 |
INPUT | ||||||||
Voltage | 220/230/240Vac | |||||||
Voltage Range | 140~300Vac | |||||||
Frequency Range | 50/60Hz (auto sensing) | |||||||
OUTPUT | ||||||||
AC Voltage Regulation (Batt. Mode) | ||||||||
±10% | ||||||||
Frequency Range | 50/60Hz ±1 Hz | |||||||
(Batt. Mode) | ||||||||
Transfer Time | Typical 4-8ms, 13ms Max. | |||||||
Waveform (Batt. Mode) | Simulated Sinewave | |||||||
BATTERY | ||||||||
Battery Voltage | 12Vdc | 24Vdc | 48Vdc | |||||
Battery Type & Number | 12 V /7Ah x 1 | 12 V / 9Ah x 1 | 12 V / 7Ah x 2 | 12 V / 7Ah x 2 | 12 V / 9Ah x 2 | 12 V / 9Ah x 2 | 12 V / 7Ah x 4 | 12 V / 9Ah x 4 |
Typical Recharge Time | 4~6 hours recover to 90% capacity | 6~8 hours recover to 90% capacity | ||||||
INDICATORS | ||||||||
LED Display(LED version) | AC Mode, Battery Mode, Overload, Fault | N/A | ||||||
LCD Display(LCD version) | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low | |||||||
PROTECTION | ||||||||
Full Protection | Short circuit, Overload , Overcharge and overdischarge protection | |||||||
ALARM | ||||||||
Battery mode | Sounding every 10 seconds | |||||||
Low Battery | Sounding every second | |||||||
Overload | Sounding every 0.5 second | |||||||
Battery Replacement Alarm | Sounding every 2 seconds | |||||||
Fault | Continuously sounding | |||||||
MANAGEMENT | ||||||||
Communication port | USB or RS232(Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC) | |||||||
OPERATING ENVIRONMENT | ||||||||
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) | |||||||
Noise Level | Less than 45dB | Less than 55dB | ||||||
PHYSICAL | ||||||||
Approx. Dimension D * W * H (mm) | 289*101*142 | 314*130*175 | 380*158*198 | 436*145*212 | ||||
Approx. Net Weight (kgs) | 4.3 | 4.9 | 7.2 | 7.8 | 10.1 | 10.5 | 20 | 23 |