Home >  OEM/ODM > OEM/ODM Services > ups> Online Transformerless UPS> MEMOPOWER Pro-Ⅲ Series (6kVA-10kVA)

MEMOPOWER Pro-Ⅲ 6-10KVA

6kVA-10kVA

  powerfactor
MEMOPOWER Pro-Ⅲ 6-10kVA is new generation small power UPS of KSTAR, both input and output are single phase, the output factor is 0.9.The efficiengy of this UPS is very high,it can achieve power saving and reduce cost of customer in result.

General Features

• N+X parallel redundancy,support maximum 4 units in parallel

• Online double conversion with full digital control 

• Optimization battery group, the quantity of battery: 16/18/20pcs (Settable) 

• Wide input voltage range:110~286Vac 

• Wide input frequency range 

 • Selectable output voltage: 208/220/230/240Vac 

• Generator compatible 

• ECO mode operation for energy saving 

• Self-testing when UPS startup 

• Multiple communication interface:RS232/USB/EPO(Relay card/SNMP card optional) 

• Maximum charging current up to 10A 

• Cold start 

• Design with maintenance switch (Optional) 

• Intelligent fan speed regulation 

• Multiple protection function:short-circuit,overload,overheat, battery overcharge and overdischarge,output low voltage and fan fault alarm


  Technical Specification  

MODEL MP Pro 6k H MP Pro 6k S MP Pro 10k H MP Pro 10k S
Capacity 6000VA/ 5400W 10000VA/ 9000W
INPUT  
Nominal voltage 208/220/230/240Vac
Input voltage range 110~286Vac
Frequency range 40~70Hz (50/60Hz Auto-Sensing)
Power factor ≥0.99
  Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%)
Bypass voltage range 240V:+15% (Optional+10%)
  Min.voltage:-45% (Optional-20%,-30%)
OUTPUT  
Output voltage 208/220/230/240Vac
Power factor 0.9
Voltage regulation ±1%
Output frequency Line Mode ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Bat. Mode (50/60±0.1%)Hz
Crest factor 3:01
Harmonic distortion (THDv) ≤2% Linear load
≤5% Non linear load
Transfer time AC mode to Bat.Mode 0ms
Inverter to Bypass 0ms
Output waveform Pure Sinewave
Overload Line Mode Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Bypass Mode 40A (Breaker) 63A (Breaker)
Efficiency 0.935
BATTERY  
Battery voltage ±96/±108/±120Vdc (Adjustable) ±120Vdc ±96/±108/±120Vdc (Adjustable) ±120Vdc
Capacity (Standard unit) 9Ah/12V (7Ah/12V optional)
Typical recharging time 6~8 hours (to 90% of full capacity)
Charging current 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
INDICATORS  
LED display Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD display Input voltage,Input frequency,Output voltage,Output frequency,Load percentage,
Battery voltage,Inner temperature& Remaining battery backup time
ALARM  
Battery mode Beeping every 4 seconds
Battery low Beeping every second
Overload Beeping twice every second
Fault Continously beeping
PHYSICAL  
Dimension W x D×H (mm) H:191 x 460 x 337 ; S:191 x 460 x 720 (With wheel)
Net weight (kg) 12.5 70 14 71.5
ENVIRONMENT  
Operating temperature 0℃~40℃
Storage temperature -25℃~55℃
Humidity range 20~95%RH @ 0~40℃ (Non condensing)
Altitude <1500m,derating required when>1500m
Noise level <55db at 1 Meter <58db at 1 Meter
STANDARDS  
Safety IEC/EN62040-1,IEC/EN62477-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

Contact US Now


Cookie Policy

By continuing to use this website, you agree to our use of cookies.Read our privacy policy>