Home >  OEM/ODM > OEM/ODM Services > ups> Online Transformerless UPS> MEMOPOWER RT Pro-Ⅲ 6-10KVA
MEMOPOWER RT Pro-Ⅲ 6-10KVA
6kVA-10kVA
 powerfactor  power factor 0.8
MEMOPOWER RT Pro-Ⅲ 6-10kva series UPS is an online double-conversion UPS providing consistent sine-wave power to your critical equipment. It supports personal computers, networks, servers, VoIP and telecommunications. With full digital control, ECO mode and compact design, it features high reliablity and energy savings. Optional external battery pack can be connected for longer backup time to keep your applications safe and running smoothly at all times.

General Features

■High power density
LCD supports Rack/Tower convertible design
N+X parallel redundancy, support a maximum of 4 units in parallel
Online double conversion with full digital control
Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
Wide input voltage range:110~286Vac
Wide input frequency range
Generator compatible
ECO mode operation for energy saving
Self-testing when UPS startup
communication interfaces: RS232/USB/EPO(Relay card/SNMP card optional)
Parallel kit default
Maximum charging current up to 10A
Cold start
Intelligent fan speed regulation
Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm

Technical Specification

MODEL MP RT 6k MP RT 10k
Capacity 6000VA/ 5400W 10000VA/ 9000W
INPUT  
Nominal voltage 208/220/230/240Vac
Input voltage range 110~286Vac
Frequency range 40~70Hz (50/60Hz Auto-Sensing)
Power factor ≥0.99
  Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%)
Bypass voltage range 240V:+15% (Optional+10%)
  Min.voltage:-45% (Optional-20%,-30%)
OUTPUT  
Output voltage 208/220/230/240Vac
Power factor 0.9
Voltage regulation ±1%
Output frequency Line Mode ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Bat. Mode (50/60±0.1%)Hz
Crest factor 3:01
Harmonic distortion (THDv) ≤2% Linear load
≤5% Non linear load
Transfer time AC mode to Bat.Mode 0ms
Inverter to Bypass 0ms
Output waveform Pure Sinewave
Overload Line Mode Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min; >150% turn to bypass mode immediately
Bypass Mode 40A (Breaker) 63A (Breaker)
Efficiency 94%
BATTERY  
Battery voltage ±96/±108/±120Vdc (Adjustable) ±120Vdc ±96/±108/±120Vdc (Adjustable) ±120Vdc
Capacity (Standard unit) 9Ah/12V (7Ah/12V optional)
Typical recharging time 6~8 hours (to 90% of full capacity)
Charging current 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
INDICATORS  
LED display Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD display Input voltage,Input frequency,Output voltage,Output frequency,Load percentage,
Battery voltage,Inner temperature& Remaining battery backup time
ALARM  
Battery mode Beeping every 4 seconds
Battery low Beeping every second
Overload Beeping twice every second
Fault Continously beeping
PHYSICAL  
Dimension W x D×H (mm) 440 x 625 x 86.5
Net weight (kg) 16 18
ENVIRONMENT  
Operating temperature 0℃~40℃
Storage temperature -25℃~55℃
Humidity range 20~95%RH @ 0~40℃ (Non condensing)
Altitude <1500m,derating required when>1500m
Noise level <55db at 1 Meter <58db at 1 Meter
STANDARDS  
Safety IEC/EN62040-1,IEC/EN62477-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8

Contact US Now


Cookie Policy

By continuing to use this website, you agree to our use of cookies.Read our privacy policy>