● Wide input voltage range 138-485Vac (Phase voltage80-280Vac)
● High input power factor,it can be up to 0.99.
● Three level inverter topology, the efficiency can be up to 96%.
● Support parallel expanded operation:maximum is 6 units.
● Large charging current
● High adaptability for load, it can connect full inductive load or capacitive load.
● Power Walk In function, it can reduce the start current impact to system,and reduce the capacity of generator.
● Optimization battery group, the quantity of battery: 10-30k(16/18/20 pcs optional), 40-80k(32/34/36/38/40 pcs optional)
● LBS function can realize 2 independent UPS system work in synchronization, enhances the reliability of the system.
● The output factor is 1.0, can meet 100% unbalanced load
● Support USB,RS485, RS232, SNMP, dry contact card
MODEL | YDC3360H | YDC3380H | YDC33100H | YDC33120H | YDC33160H | YDC33200H | ||
Capacity (VA/Watts) | 60k / 54k | 80k / 72k | 100k / 90k | 120k / 108k | 160k / 144k | 200k / 180k | ||
INPUT | ||||||||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | |||||||
Operating voltage range |
138~485Vac for 40%load; 305~485Vac for full-load | |||||||
Operating frequency range |
40~70Hz | |||||||
Power factor | ≥0.99 | |||||||
Bypass voltage range |
220Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 230Vac Max.voltage: +20%(optional +10%,+15% ) 240Vac Max.voltage: +15%(optional +10% ) Min. voltage: -45% (optional -20%,-30%) Frequency synchronize tracing range: ±10% |
|||||||
generator input | Support | |||||||
Harmonic distortion (THDi) |
≤3%(100% non-linear load) | |||||||
OUTPUT | ||||||||
Rated voltage | 380/400/415Vac(3Ph+N+PE) | |||||||
Power factor | 0.9 | |||||||
Voltage regulation |
±1% | |||||||
Frequency | Line mode | synchronize with input; when input frequency >±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz | ||||||
Bat. mode | 50/60(±0.1)Hz | |||||||
Crest factor | 3:1 | |||||||
Harmonic distortion (THDv) |
≤2% with linear load ≤4% with non-linear load |
|||||||
Efficiency | 96% | |||||||
BATTERY | ||||||||
Battery voltage | Optional Voltage: ±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/ 46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 30 pcs default, 36~50 pcs output power factor 1.0; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
|||||||
Charging current (A)(Charging current can be set according to battery capacity installed) |
20A(Max.) | 40A(Max.) | 60A(Max.) | |||||
SYSTEM FEATURES | ||||||||
Transfer time | Utility to Battery : 0ms; Utility to bypass: 0ms | |||||||
Overload | ≤110% overload 60 min; ≤150% overload 1 min,to Bypass Bypass mode:135% overload long time; >1000% overload 100 ms |
|||||||
Backfeed protection |
Support | |||||||
Alarm | Overload, utility abnormal, UPS fault, battery low, etc. |
|||||||
Protection | Short circuit, overload, over temperature, battery low, fan fault alarm. | |||||||
Remote LCD | Support | |||||||
Communication interface |
USB, RS232, RS485, Parallel port, dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional) | |||||||
ENVIRONMENT | ||||||||
Operating temperature | 0~40℃ | |||||||
Storage temperature |
25~55℃(No battery) | |||||||
Humidity range | 0~95% (Non-condensing) | |||||||
Altitude | <1500m. When >1500m, derating power for use | |||||||
Noise level | <58dB | <60db | <62db | <63dB | <65dB | |||
PHYSICAL | ||||||||
Dimension D×W×H (mm) |
828x250x868 | 850x442x1100 | ||||||
Net weight (kg) | 83 | 143 | 147 | 152 | 200 | 230 | ||
STANDARDS | ||||||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |