Home >  OEM/ODM > OEM/ODM Services > ups> Online Transformerless UPS> MEMOPOWER II (6-10kVA)
MEMOPOWER II
6-10kVA
 
MEMOPOWER II 6-10kVA ,both input and output are single phase,and output factor is 0.8. It can supply reliable power to data center, crucial load, meet the high reliability of customer for UPS, It is with high efficiency and can supply comprehensive power protection for user.
General Features

● N+X parallel redundancy

● Online double conversion with DSP control

● Input current harmonic: <3%

● Optimization battery group, the quantity of battery: 16/18/20 pieces (optional)

● High output power factor at 0.8PF

● Wide input voltage range: 120~276Vac

● Wide input frequency range(50Hz: 45~55Hz / 60Hz: 54~66Hz)

● Support generator input

● Support economic(ECO) operation mode

● Self-testing when UPS startup

● Options: SNMP card/Relay card/ Parallel card

● Cold start

Technical Specification
MODEL MEMO S 6kVA  MEMO H 6kVA MEMO S 10kVA   MEMO H 10kVA
Capacity (VA/Watts) 6K/4.8K 10K/8K
INPUT 
Nominal Voltage 220/230/240Vac
Operating  Voltage
 Range
120~276Vac
Frequency Range 50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)
Power Factor ≥0.99
Bypass voltage range Max.voltage: 220V: +25%(optional +10%,+15%,+20% )
Bypass voltage range    230V: +20% (optional +10%,+15%)
240V: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)
Bypass frequency
 range 
Frequency protection range:±10%
ECO range  Same as the bypass
Harmonic distortion
(THDi)
<3%(100% linear load)
Generator input Support
OUTPUT  
Output Voltage  220/230/240Vac
Power Factor 0.8
Voltage Regulation ±1%
Frequency Line Mode ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Bat. Mode 50/60(±0.1)Hz
Crest Factor 3:1
Harmonic Distortion
 (THDv)
≤2% with linear load 
≤5% with non-linear load 
Efficiency >91%
BATTERY
Battery voltage  ±96/108/120Vdc(optional)
Capacity
 (standard unit)
12V/7Ah/9Ah
Typical recharging
 time
6~8 hours (to 90% of full capacity)
Charging current  1A(Standard unit) ; Max.current 6A(Long run unit); (Charging current can be set according to battery capacity installed)
SYSTEM FEATURES
Transfer time Mains to battery:0ms; Mains to bypass:0ms
Overload Line Mode Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediately
Bypass Mode 40A(Breaker) 60A(Breaker)
Short circuit  Hold whole system
Overheat Line Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediately
Battery low Alarm and switch off
Self-diagnostics Upon power on and software control 
Battery  Advanced battery management 
Audible & Visual
 alarms
Line failure, Battery low, Overload, System fault
LED & LCD display Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS fault
LCD display  Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage,
Inner temperature & Remaining battery backup time
Communication
 interface
Interface  RS232,USB,SNMP card(optional), Parallel card(optional), Relay card (optional)
ENVIRONMENT
Operating
 temperature
 0℃~40℃
Storage
temperature
-25℃~55℃
Humidity range  0~95% (non-condensing)
Altitude  < 1500m
Noise level <55dB
PHYSICAL
Dimension
 D×W×H (mm)
502×250×616 (S) / 481×220×438 (H)
Net weight (kg)   62/18  64/20
STANDARDS
Safety   IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8